Oculus pentacam interpretation manual pdf download. Corneal topography and tomography dharwadkar s, nayak b k. Each patient underwent slitlamp examination, pentacam hr scheimpflug tomography, and placido disk topography and aberrometry itrace, software version 4. The high resolution ccd chip and optimized optic design measures up to 1 8,000 true elevation points.
Instead of manually placing the cursor on pachymetry images and automatically estimating corneal thickness at the cursor point, we exported the u12 files containing the specific raw data from the pentacam hr system and tabulated them in excel files using the pentacam hr software. Keratoconus and pentacam pdf keratoconus, the most common corneal ectasia, is a progressive corneal figure 8. Page 2 dicom conformance statement pentacam pentacam hr 1 conformance statement overview oculus pentacam is a measuring device for examining the front part of the eye. The lens changes its surface curvature during accommodation so the eyes can focus on objects at different distances. The pentacam is a powerful scanner for segments of the eye, based on the scheimpflug camera measurements. We performed a retrospective, statistical and crosssectional study of eyes affected by keratoconus and normal eyes. Rajpal, md,3,5 on behalf of the united states crosslinking study group purpose. Comfort and comprehensive assessment of the anterior eye segment are joined in this extraordinary ensemble to support your daily diagnostic routine. The recordings of the oculus lunch symposium at escrs 2017 are available. The aim of this study was to determine the agreement between pentacam hr scheimpflug imaging, oculus and orbscan ii scanning slit topography, bausch. This procedure may be indicated when photodocumentation is required to track the progression or lack of progression of an eye condition, or to document the progression of a particular course of treatment. Pentacam hr measurements were taken without use of topical anesthesia and with the patient keeping both eyes open. With the pentacam, you can organize your preoperative planning with more ease and safety than ever before.
The pentacam hr produces sharp and brilliant images with its outstanding hardware. Reliability of pentacam hr thickness maps of the entire. It is a robust invention that helps ophthalmologists in investigating the corneal anterior. Study patients discontinued contact lens wear for at least 2 weeks. Udfyld nedenstaende formular eller ring pa 2028 3654 sa vender vi snarest tilbage. While performing a rotating scan the pentcam hr captures up to 100 highresolution scheimpflug images to provide a detailed analysis of the cornea. Oculus pentacam hr interpretation manual 216 pages highresolution rotating scheimpflug camera system for anterior segment analysis. The oculus keratograph 5m the oculus keratograph 5m is an advanced corneal topographer with a builtin real keratometer and a color camera optimized for external imaging. The pentacam hr is our high resolution model, measuring up to 1 8,000 true elevation points. Pentacam and javal mink and maxk readings were very high r0. Your patients will be given a stateoftheart presentation of the examination results, making it possible to discuss treatment options.
Previous studies have shown that in the process of accommodation, the focus is mainly adjusted by changing the radius of anterior lens surface curvature ral, while the radius of. The study aimed to characterize the entire corneal topography and tomography for the detection of subclinical keratoconus kc with a zernike application method. Central corneal thickness measurement with pentacam. The new software of the pentacam hr allows measure ment of the corneal power taken. Pentacam hr the professional model the pentacam hr is our highresolution professional model. Cataract progression over time is depicted and made understandable. To determine the agreement of measurements between color lightemitting diode corneal topography cassini and scheimpflug camera keratometry pentacam hr. Corneal asymmetry analysis by pentacam scheimpflug tomography. Unique features include examining the meibomian glands, noninvasive tear film breakup time and the tear meniscus height measurement and evaluating the lipid layer. This rotating process allows rapid capture of images in different meridians, and therefore threedimensional elevations. It is equipped with a high resolution ccd chip and optimized optics.
Pentacam hr scheimpflug images render impressive representations of iols and phakic iols. Cannula ejection into the cornea during wound hydration. For a detailed analysis of the cornea up to 100 scheimpflug images can be captured during the rotating scan. With its brighter and optimized optic it offers you bril. The pentacam pentacam hr software allows customized and objective standardized evaluation of corneal optical densitometry. It measures the anterior corneal keratometry using the data from six light reflections oriented in a hexagonal pattern approximately 2. Fuchs endothelial dystrophy showing characteristic guttae dark areas and reduced endothelial cell density on confocal microscopy.
The userfriendly software gives you all of the important information for every operation. Comparison between pentacam hr and orbscan ii after hyperopic. K measurements taken with manual or automated keratometers. Repeatability and reproducibility of the oculus pentacam hr. Oculus pentacam oculus twinfield 2 presurgical consultation break room for practice staff pentacam hr the professional model our highend model is our highresolution pentacam hr. Imaging techniques for assessing the structure and function of the cornea and anterior segment are crucial for diagnosing and treating a wide variety of ocular diseases. Pentacam hr examination was performed for all participants, and the data of all pachymetric, aberrometric, and topometric indices was extracted for the study population. Reading the pentacams maps for detecting keratoconus 3. Pentacam hr manuals and user guides for oculus pentacam hr. United states multicenter clinical trial of corneal. Pentacam pentacam system uses rotating scheimpflug imaging for noninvasive and threedimensional anterior segment evaluation. Additionally, the bad performs regression analysis on. Success is visible when comparing images before and after iridectomy or corneal surgery. It is as different as a ct scan and a regular x ray.
Step by step reading pentacam topography request pdf. Characteristic of entire corneal topography and tomography for the detection of subclinical keratoconus with zernike polynomials using pentacam. A guide to interpreting corneal tomography consider using a systematic approach for reading and interpreting corneal tomography. Nov 17, 2015 in this study, the hr mode was used referred to as pentacam hr. Quantitative assessment of anterior chamber volume using. During corneal tunnel hydration following a successful phacoemulsification procedure, a hydration cannula on a luer lock syringe was forcefully ejected into the corneal stroma. The 95% loa between pentacam and javal in measuring mink and maxk were 0. Reimbursement for tests with the oculus pentacam oculus. External ocular photography 92285 indications and limitations of coverage andor medical necessity. The contact lens fitting program featuring an integrated and expandable database with over 65,000 lens geometries is included. This measurement helps detect and manage corneal pathology associated with corneal thinning and discriminate between keratoconus and contact lensinduced corneal thinning. The pentacam hr is a highresolution instrument that used a 1. The iolmaster carl zeiss meditec, germany is partial coherence interferometer used for anterior segment measurements. While rotating around the eye, the pentacam creates scheimpflug images of the front part of the eye through varying axes.
Pentacam hr criteria for curvature change in keratoconus. Used oculus pentacam hr ophthalmology general for sale. United states multicenter clinical trial of corneal collagen crosslinking for keratoconus treatment peter s. In the untreated group, each eye received 3 consecutive scans using the pentacam hr, and ekr values in all central corneal zone, the true net power knet and the simulated k simk were obtained. Q what tests can be performed with the oculus pentacam and pentacam axl. Pdf pentacam hr indices variation in normal corneas with. Pentacam software usb drive and should be read by all users prior.
Therefore, fmount and large format cmount lenses are needed to prevent image. To evaluate the effect of variable corneal thickness on pentacam hr diagnostic indices in normal corneas. Pentacam hr criteria for curvature change in keratoconus and. Comparison of keratometric values using javal keratometer. The crystalline lens is the most dynamic optical element of the human eyes. The belinambrosio enhanced ectasia display bad on the pentacam oculus optikgerate gmbh simplifies interpretation of the elevation map, with the display of anterior and posterior elevation data shown relative to a standard bestfitsphere calculated at an optical zone fixed at 8. Shiraz university of medical science khalili hospital.
Accurate measurement of corneal thickness is an essential component of an advanced ophthalmologic examination. An optional feature is the 3d piolsimulation software module including aging prediction. Central corneal thickness measurement with pentacam, orbscan. The pentacam classic can be expanded to include further optional software modules at any time. Comparison of radius of anterior lens surface curvature. The pentacam provides optical distortioncorrected data of the posterior cor. It is displayed as a color coded map over its full depth and area and can be assessed individually in different layers and zones. Keratoconus ectasia detection with the oculus pentacam. A the pentacam is a multipurpose diagnostic instrument for evaluating the anterior segment. It uses a monochromatic slitlight source blue led at 475 nm to measure anterior segment topography. The pentacam hr stands out by virtue of its bright optics, which make for extremely sharp. Oculus pentacam manuals manuals and user guides for. Quantitative assessment of anterior chamber volume using slit. The manual adjustment focal plane allows the instrument to be set for.
Reimbursement for tests with the oculus pentacam oculus faq. Doyle stulting, md, phd,2 david muller, phd,3 daniel s. The initial sample consisted of topographies obtained by oculus pentacam hr of 151 eyes from 96 patients. Tonys super specialty eye hospital, aluva introduction pentacam is a device that does an anterior segment tomography as opposed to a topography in most other topographers. Comparison of keratometric measurements between color. New corneal assessment index from the relational thickness and other oculus values cairo index maged m roshdy,1,2 sherine s wahba,1,2 ramy r fikry2,3 1ophthalmology department, ain shams university, cairo, egypt. Pentacam hr analyzes the tomographic images obtained from a single rotating camera, whereas cassini is a new topographer that uses a multicolor red, yellow, and green spot pattern, which analyses the specular reflection using 679 lightemitting diode led spots superimposed on the cornea. Apr 26, 2019 pentacam hr analyzes the tomographic images obtained from a single rotating camera, whereas cassini is a new topographer that uses a multicolor red, yellow, and green spot pattern, which analyses the specular reflection using 679 lightemitting diode led spots superimposed on the cornea. Comparison of anterior segment biometric measurements. Topographic data were obtained before surgery and 1, 3, 6, and 12 months after surgery. The cannula exited from the posterior aspect of the cornea and lodged in the anterior.
The oculus pentacam hr premium is a unique combination of optimized design and revolutionary technology. Corneal irregularities as well as injuries, implantations and refractive interventions are made amazingly visible. Pdf to evaluate the precision repeatability and reproducibility of the pentacam hr highresolution tomographer oculus, wetzlar, germany across a. Pentacam screening forpentacam screening for keratoconuskeratoconus with special attention towith special attention to belin ambrosio enhancedbelin ambrosio enhanced ectasia displayectasia display m. In addition to the basic software you receive software packages for refractive surgery and cataracts, pns pentacam nucleus staging and cataract analysis, the holladay report and the contact lens fitting module. Iol calculation for postrefractive patients the oculus pentacam hr.
Steep k, flat k, mean k, astigmatism, and axis for both anterior and posterior corneal surface. The correlation between pentacam and javal measurements of keratometric. Characteristic of entire corneal topography and tomography. The pentacam hr is equipped with a software package that leaves nothing to be desired. Comparison of anterior segment biometric measurements between. The current version of these documents and the interpretation guide are on every.
In this study, the hr mode was used referred to as pentacam hr. The pentacam images the anterior segment of the eye by a rotating scheimp. Imaging techniques for assessing the structure and function of the cornea and anterior segment are crucial for. To report a case of iatrogenic corneal perforation from an ejected cannula. United states multicenter clinical trial of corneal collagen. We have 1 oculus pentacam hr manual available for free pdf download. New corneal assessment index from the relational thickness. With its optimised optics it offers you absolute image quality. Corneal asymmetry analysis by pentacam scheimpflug. The current retrospective study investigated 117 right eyes of 117 healthy patients before cataract surgery from june 2017 to july 2017. Download as pdf for best results, please view in mozilla firefox. Pentacam eye left type of exam 25 hr p atient last name first name dato 8 id number patient list lastname 3 demo refractive post lasik 07021961 flap fl. View and download oculus pentacam interpretation manual online.
927 884 1225 1567 1578 38 419 1101 272 1345 448 71 858 484 463 146 1199 776 417 116 732 773 1166 986 25 707 1437 1215 639 502 873 1426 1034 754 1402 263